Sheet1 This Spreadsheet estimates values of thermomechanical noise and position detection sensitivity for capacitive detection, using rectangular cantilevers To find values, change any values highlighted in green. Note the units in the adjacent column. The highlighted cells in blue gives sensitivity estimates The cells highlighted in yellow give values for the circuit analysis as well as circuit component values. ALL VALUES ARE IN SI UNITS UNLESS OTHERWISE NOTED GaAs Capacitive Scheme Parameters Thickness is 30.00 nm The length is 10.00 Microns and width is 3.00 Microns for a gap of 3.00 Microns Beam Paramters Young's Modulus E 8.55E10 Pa Boltzman 1.38E-23 SI units Thickness in m t 3.00E-08 m Q 15000 Width in m W 3.00E-06 m T 4.2 K Length in m L 1.00E-05 m density 5320 kg/m3 Area of the cantilever Area 3.00E-11 m2 = 3.00E-07 cm2 Capacitive Gap in m Cap. Gap 3.00E-06 m = 3.00E+00 um2 Mass of cantilever m 1.15E-15 SI units Stiffness k 1.73E-03 N/m Resonance Frequency fc 1.95E+05 Hz Frequency w0 1.17E+06 4kkT 4.01E-25 2pifQ 5.78E+10 Thermomechanical Noise Calculated Sf-thermal 0 Sd due to thermal noise 0 Capacitance calculations Capacitance of the cantilevers C 8.85E-17 Calculated Pull-in in volts Pull-in Vol 10.8342676694 Volts 10834.2676693999 Millivolts 80% of pull-in voltage 8.6674141355 Voltage Noise of amplifier Amplifier Noise 50 nV/.Rt. Hz If parasitic capacitance can be resonated away Position detection sensitivity with parasites Sd 3.74E-10 No Parasites (Sd) 0 Corresponding force sensitivity with parasites Sf-detector 0 Sf 2.00E-21 Circuit Analysis The following are values for an equivalent circuit to the mechanics Lm 17576.8989328311 H Cm 4.14E-17 F This is the 'mechanical' impedance Rm 1.37E+06 ohm This is the required tank circuit impedance Z-tank 8285.433712088 ohm using Z-LC=SQRT(Rm*50) Corresponding L of tank L-tank 7.07E-03 H Q for Tank 1.66E+02 C of tank C-tank 0.0000000001 F Parasitic Capacitance estimates Assuming 220x220 um total area, bond pads that are 150X150 Area of bond pads 0.0000000484 Assuming a projection of 50um length and 20um width Projection area 0.000000001 Total 0.0000000494 Bond_pad Capacitance 1.79E-12 F Wirebond Capacitance 1.00E-13 HEMT Input 2.10E-14 Total Parasites 1.91E-12 Casimir Force Force 5.93E-11 N Force Required to bring plates together Force 5.19E-09 N Is this Design OK for Casimir Force? Yes, Casimir Forces are not sufficient to cause stiction Sheet2 Sheet3